Resumen
We are adopting a new airworthiness directive (AD) for certain The Boeing Company Model 747-400, 747-400D, and 747-400F series airplanes. This AD was prompted by a determination that a certain fastener type in the fuel tank walls has insufficient bond to the structure, and an electrical wiring short could cause arcing to occur at the ends of fasteners in the fuel tanks. This AD requires the installation of new clamps and polytetrafluoroethylene (TFE) sleeves on the wire bundles of the front spars and rear spars of the wings. This AD also requires inspecting the existing TFE sleeves under the wire bundle clamps for correct installation, and replacement if necessary. We are issuing this AD to prevent potential ignition sources in the fuel tank in the event of a lightning strike or high-powered short circuit, and consequent fire or explosion.
Detalles de la directiva
Número de AD
FAA-2016-3986
Número de documento
2016-22707
Tipo
Rule
Fecha de publicación
October 7, 2016
Fecha de entrada en vigor
November 14, 2016
Fabricante afectado
The Boeing Company
Criticidad
routine
Emergencia
No
Docket ID
Docket No. FAA-2016-3986