The FAA is adopting a new airworthiness directive (AD) for all Honeywell International Inc. (Honeywell) ALF502L, ALF502L-2, ALF502L- 2A, ALF502L-2C, ALF502L-3, ALF502R-3, ALF502R-3A, ALF502R-4, ALF502R-5, ALF502R-6, LF507-1F, and LF507-1H model turbofan engines. This AD was prompted by a report of an engine experiencing an uncontained release of low-pressure turbine (LPT) blades. This AD requires initial and repetitive visual inspections of the overspeed fuel solenoid valve assembly and the fuel filter outlet. Depending on the results of these inspections, the AD may require inspection of the adjacent fuel system tube assemblies as well as replacement or overhaul of the overspeed fuel solenoid valve assembly. This AD also requires periodic overhaul of the overspeed fuel solenoid valve assembly. The FAA is issuing this AD to address the unsafe condition on these products.
Detalles de la directiva
Número de AD
FAA-2020-0394
Número de documento
2020-20374
Tipo
Rule
Fecha de publicación
September 16, 2020
Fecha de entrada en vigor
October 21, 2020
Fabricante afectado
Honeywell International Inc. Turbofan
Criticidad
routine
Emergencia
No