Summary
We are superseding an existing airworthiness directive (AD) for all Turbomeca S.A. Arriel 1E2, 1S, and 1S1 turboshaft engines. That AD currently requires a one-time inspection and torque check of the 3- way union plug installed on all fuel control units (FCUs). This new AD requires the same actions. This AD also requires reduction of the applicability to certain FCUs and references an updated service bulletin containing additional detailed information to identify the non-compliant "red disk." This AD also requires replacement of the plug before further flight if it is found to be non-compliant, and prohibits installation of FCUs that have not passed the 3-way union plug inspection and torque check. This AD was prompted by Turbomeca S.A. informing us that FCUs manufactured, repaired, or overhauled after March 31, 2008, do not require inspection. We are issuing this AD to prevent fuel leaks, which could result in a fire and damage to the helicopter.
Directive Details
AD Number
FAA-2008-0681
Document Number
2012-28637
Type
Rule
Publication Date
December 3, 2012
Effective Date
January 7, 2013
Affected Manufacturer
Turbomeca S.A. Turboshaft
Criticality
important
Emergency
No
Docket ID
Docket No. FAA-2008-0681
Topics
Official Documents
Automated AD compliance tracking
AeroCopilot matches ADs to your aircraft and tracks compliance status. Included in every plan from $9.99 monthly.
Unlock AD-to-aircraft matching, compliance tracking, recurrence schedule with a free AeroCopilot account.
Sign up free to unlock AD-to-aircraft matching, compliance tracking, recurrence scheduleFree forever · No credit card · Sourced directly from FAA & NOAA pipelines