Summary
The FAA is adopting a new airworthiness directive (AD) for all General Electric Company (GE) GEnx-1B64, -1B64/P1, -1B64/P2, -1B67, - 1B67/P1, -1B67/P2, -1B70, -1B70/75/P1, -1B70/75/P2, -1B70/P1, -1B70/P2, -1B70C/P1, -1B70C/P2, -1B74/75/P1, -1B74/75/P2, -1B76/P2, and -1B76A/P2 model turbofan engines. This AD was prompted by a report of a crack in the outer fuel manifold causing fuel leakage. This AD requires initial and repetitive visual inspections of the cushioned loop clamp (p-clamp) and, depending on the results of the inspection, a spot fluorescent penetrant inspection (FPI) of the outer fuel manifold. Depending on the results of the FPI, this AD may require replacement of the outer fuel manifold. This AD also requires initial and repetitive replacements of the p-clamp. The FAA is issuing this AD to address the unsafe condition on these products.
Directive Details
AD Number
FAA-2020-0653
Document Number
2021-03571
Type
Rule
Publication Date
February 23, 2021
Effective Date
March 30, 2021
Affected Manufacturer
General Electric Company Turbofan
Criticality
routine
Emergency
No
Docket ID
Docket No. FAA-2020-0653
Topics
Official Documents
Automated AD compliance tracking
AeroCopilot matches ADs to your aircraft and tracks compliance status. Included in every plan from $7.99 monthly.
Unlock AD-to-aircraft matching, compliance tracking, recurrence schedule with a free AeroCopilot account.
Sign up free to unlock AD-to-aircraft matching, compliance tracking, recurrence scheduleFree forever · No credit card · Sourced directly from FAA & NOAA pipelines